Source: Yamane Y, Yoshioka N, Seo T. Effects of water cup cleaning on drinking behaviour, water intake, and milk yield of lactating dairy cows in tie-stall barns. Animals (2026) 16:1634. doi:10.3390/ani16111634
Effects of Water Cup Cleaning on Drinking Behaviour, Water Intake, and Milk Yield of Lactating Dairy Cows in Tie-Stall Barns
Authors: Yurina Yamane, Natsuki Yoshioka, Tetsuya Seo
Department of Animal Science, Obihiro University of Agriculture and Veterinary Medicine, Obihiro 080-8555, Japan
Correspondence: seo@obihiro.ac.jp · Tel.: +81-155-49-5425
Simple Summary
Dairy cows kept in tie-stall barns usually drink from small water cups that release water
when the cow pushes a valve. If these cups are not cleaned regularly, feed particles, slime,
and algae can build up. Dirty cups may make cows less willing to drink or cause them to
drink less efficiently. In this study, we cleaned heavily fouled water cups and observed how
cows changed their drinking behaviour. Each cow was compared with herself before and
after cleaning. After the cups were scrubbed, cows drank more water each time they visited
the cup, which increased their total daily water intake. However, milk yield did not differ
before and after cleaning during the short-term observation period. These results indicate
that cleaning water cups can improve drinking efficiency and water hygiene even in the
absence of short-term changes in milk yield. Regular cleaning of water cups is therefore a
practical and useful management practice that supports appropriate daily management
and animal welfare in tie-stall systems.
Abstract
Water cups in tie-stall barns often remain uncleaned for long periods, allowing organic
matter and biofilms to accumulate, which may reduce drinking efficiency, defined as
water intake per drinking event rather than drinking frequency, and increase hygienic
risks, including potential bacterial contamination, in dairy cows. This study examined
the short-term effects of cleaning heavily fouled water cups on drinking behaviour, water
intake, and milk yield in lactating Holstein cows. Twenty-four cows were observed on a
baseline day and again after a one-day adaptation period following cup cleaning, using a
within-animal comparison. Cleaning significantly increased total daily water intake by approximately 5 L (p < 0.05) and water intake per drinking bout by approximately 2 L (p < 0.01),
while drinking frequency, milk yield, and maintenance behaviours remained unchanged.
Temperature–humidity conditions were similar across observation days, indicating that
increased intake was attributable to improved water hygiene rather than environmental
variation. Although cleaning enhanced drinking efficiency, the magnitude of increased
water intake was insufficient to affect short-term milk yield. These findings demonstrate
that regular water cup cleaning is a practical management practice that improves drinking
efficiency and water hygiene, with potential implications for cow health and welfare.
Keywords
drinking behavior; drinking efficiency; water intake; water hygiene
1. Introduction
Water is a fundamental nutrient for animals, including cattle. Experimental restriction
of water availability alters physiological responses in growing and fattening cattle, resulting
in reduced body weight and feed intake [1]. Restricted water intake has also been shown
to reduce feed consumption and impair nutrient utilization in Zebu cattle [2]. In lactating
cows, limiting water availability to 50% of the normal intake has been shown to reduce
lying time and milk yield [3]. A recent review emphasized that insufficient water access or
poor water quality can reduce milk production and compromise animal welfare [4].
Water intake in dairy cows is influenced by multiple nutritional and environmental
factors. According to NASEM [5], water requirements depend primarily on dry matter intake,
milk yield, diet composition, and ambient temperature. Previous studies indicate that water
intake in lactating Holstein cows averages around 80 L/day and may reach approximately
100 L/day depending on production level and environmental conditions [6,7].
Season has also been reported to influence drinking behaviour. Holter and Urban [8]
observed a seasonal trend in free water intake, with higher values in June and lower values
in December. Similarly, Moncada and Hsia [9] reported average intakes of approximately
62 L/day in summer and 39 L/day in winter under tropical conditions. Although these
values are lower than those reported for high-producing cows fed drier TMR, they provide
useful reference information on seasonal variation in water intake.
In tie-stall barns, dairy cows typically drink from push-valve water cups, often with
a cup positioned between two adjacent cows. Poor water quality in outdoor sources can
reduce intake and performance because cattle tend to avoid contaminated dugouts and
prefer clean trough water [10]. On many commercial farms, water cups remain uncleaned
for prolonged periods, allowing organic matter and biofilms to accumulate and creating
niches for pathogens [11,12]. Continued use of contaminated cups may suppress cows’
drinking behaviour, and regular scrubbing and proper management are necessary to
ensure water quality. Japanese national guidelines emphasize the importance of hygienic
management of watering facilities [13], although they do not provide objective criteria for
assessing water cup cleanliness in tie-stall barns. Practical criteria such as regular cleaning
frequency and visible assessment of contamination are required in farm management.
Recent research indicates that drinking facilities on dairy farms can become microbially
contaminated, particularly when biofilm, an adhesive matrix formed by microorganisms
attached to surfaces, accumulates on trough surfaces. High temperatures are associated
with increased bacterial contamination, which may allow dirty troughs to act as potential
reservoirs of pathogenic and antimicrobial-resistant bacteria [14]. Such contamination
may reduce water palatability and discourage drinking, as cows may avoid water with
unpleasant odour or taste, and may also increase the risk of waterborne infections. This
evidence suggests a dual impact of poor water hygiene on both drinking behaviour and
animal health.
In loose housing systems, cows move freely and waterers are more exposed to manure
contamination, which increases the risk of waterborne infections. In contrast, cows in tiestall barns are individually restrained and have access to only a single water cup, meaning
they cannot avoid contaminated drinking devices. Cleaning of drinking devices has been
shown to alter drinking behaviour in free-stall and pasture systems [15,16], however, these
studies did not assess milk yield. Furthermore, none have evaluated the effects of water cup
cleaning on drinking behaviour or milk yield in tie-stall barns without access to alternative
water sources. This represents an important gap in understanding how water cup hygiene
affects hydration and productivity under confined housing conditions.
We therefore hypothesized that cleaning heavily fouled water cups would improve
drinking efficiency and increase water intake in lactating dairy cows kept in tie-stall
barns. To test this hypothesis, we conducted a within-animal comparison under similar
environmental conditions, measured drinking behaviour, water intake, and milk yield
before and after cleaning. This framework was designed to isolate the immediate effects of
improved water hygiene on drinking behaviour and water intake dynamics in dairy cows.
2. Materials and Methods
2.1. Study Farm
The study was conducted on a commercial dairy farm located in the Tokachi region
of Hokkaido, Japan. The herd consisted of 73 Holstein cows housed in a tie-stall barn
with a tie-rail system (commonly referred to as a New York–style tie stall). The average
annual milk yield was 11,402 kg per cow, with two cows sharing each water cup. Feed was
provided by an automatic feeder seven times daily, at 04:00–05:00, 06:20–07:20, 09:30–10:30,
12:30–13:30, 15:30–16:30, 19:00–20:00, and 22:00–23:00.
Cows were fed a total mixed ration (TMR) consisting of 40–50 kg of corn silage and
grass silage mixed at a 3:2 ratio (weight/weight), supplemented with 3 kg of beet pulp,
concentrate, and rumen-undegradable protein (RUP). Concentrate was initially offered
at 4 kg immediately after calving and increased by 0.25 kg per day until peak lactation.
At peak lactation, concentrate allowance was 9.5 kg for primiparous cows, 10.5 kg for
second-lactation cows, and 11.0 kg for cows in their third or later lactations. RUP was
supplied at 1.0 kg for primiparous cows, 1.5 kg for second-lactation cows, and 2.0 kg for
cows in their third or later lactations, and was discontinued once the cows were confirmed
pregnant. All feed amounts are expressed on an as-fed basis, per cow per day. Cows were
milked twice daily, at 05:20–06:50 and 16:45–18:15, using a pipeline milking system. Teats
were cleaned and dried before milking, and post-milking teat disinfection was performed
after cluster removal.
2.2. Study Design
The study was conducted over two separate periods totaling 48 days, from 5 to
31 October and from 5 to 25 November 2019. Each cow was subjected to a three-day
observation period. On Day 1, water intake, milk yield, and behaviour were recorded
using water cups that had not been cleaned. Prior to this observation, the inner surfaces of
the water cups at the study farm had not been scrubbed for several years; thus, the Day 1
measurements reflected a long-term unclean condition. Subsequently, baking soda was
sprinkled inside the water cups, and they were scrubbed with a brush to ensure cleanliness.
After cleaning, all water cups were thoroughly rinsed with clean water to remove any
residual baking soda and to minimize potential effects on taste or odour. Day 2 served
as an adaptation period to the cleaned water cups, during which no measurements were
taken. On Day 3, water intake, milk yield, and behaviour were recorded again using the
cleaned water cups. This protocol enabled within-animal comparisons between pre- and
post-cleaning conditions.
2.3. Water-Cup Fouling Score
Water cup cleanliness was assessed based on the Animal Welfare Assessment Protocol
for Dairy Cattle [17], which defines drinking facilities as being free from contamination
by spoiled feed particles, slime, feces, algae, or similar substances. Four contamination
types—spoiled feed particles, slime inside the cup, slime on the back of the pusher plate,
and algae growth—were evaluated. Each contamination type was scored on an ordinal
scale from 0 (no contamination) to 2 or 3, depending on the contamination category defined
in Table 1, with higher scores indicating more severe fouling. The fouling score for each
water cup was calculated as the sum of the scores for the four contamination types.
| Score | Contamination Type | Definition |
|---|---|---|
| 0 | Spoiled feed particles | No spoiled feed particles present in the cup |
| 1 | A small amount of spoiled feed particles present on the bottom of the cup | |
| 2 | Spoiled feed particles covering the entire bottom surface of the cup | |
| 0 | Slime inside cup | No slime present |
| 1 | Slime present directly below the spout | |
| 2 | Slime present in areas other than directly below the spout | |
| 0 | Slime on back of pusher plate | No slime present. |
| 1 | Slime present up to 3 cm from the paddle tip | |
| 2 | Slime present up to 10 cm from the paddle tip | (approximately half the paddle length) |
| 3 | Slime covering the entire paddle surface. | |
| 0 | Algae growth | No algae present |
| 1 | Algae present directly below the spout | |
| 2 | Algae present in areas other than directly below the spout |
2.4. Experimental Cows
A total of 38 iron push-valve–type water cups were installed in the tie-stall barn. Of
these, 6 cups had a capacity of 4600 mL, while the remaining 32 had a capacity of 4000 mL.
This study focused exclusively on the 32 cups of identical capacity. Immediately before
the start of the survey on 1 October 2019, these cups were scored according to the fouling
categories defined in Table 1 to determine the fouling score of each cup.
Lactating cows using the selected cups were excluded if they met any of the following criteria:
a.
Insufficient milk records or cows not past their estimated peak lactation day: fewer
than three official test-day milk records, or not yet past their estimated peak lactation
day, as determined by the Multiple Trait Prediction (MTP) method based on Wilmink’s
lactation curve model [18]. These criteria were applied because reliable estimation of
lactation performance requires multiple records, and cows in early lactation experience
increasing milk yield that strongly drives water intake [19], making it difficult to
isolate the effect of water cup cleaning on production.
b.
Mastitis treatment: cows under treatment for mastitis, as the disease induces a decline
in milk yield and would confound evaluation of the effect of water cup cleaning [20].
c.
Advanced lactation: cows at ≥300 days in milk, as they were likely to enter the dry
period and leave the barn during the study.
After applying these criteria, 28 lactating cows using 16 water cups with fouling scores
of 3–5 were retained in the final experimental cohort. The mean fouling score of the selected
water cups was 4.4 ± 0.6 (mean ± SD).
2.5. Water Intake Measurement
Water intake was recorded on the observation days described in Section 2.2 during
four daily intervals—04:00–08:00, 09:30–11:30, 12:30–14:30, and 15:30–18:30—for a total
of 11 h per day. Because drinking frequency and volume increase in conjunction with
feeding [21], and peak intake coincides with both feeding and milking times [6,22–24], each
recording period was aligned with these events.
Data collection began when the automatic feeder started operating. For the first three
intervals, recording ceased one hour after the final feeding; for the 15:30–18:30 interval,
it ended 15 min after the last milking. Milking occurred during both the 04:00–08:00 and
15:30–18:30 periods. The detailed procedures for measuring water intake are described in
the following sections.
2.5.1. Water Intake per Drinking Event
Water intake per bout was calculated as:
residual volume before drinking + dispensed volume −residual volume after drinking,
where dispensed volume was determined by multiplying the cup’s mean flow rate (L/s)
by the duration of water flow (s).
2.5.2. Residual Water Volume in the Water Cup
A study was conducted to derive an equation for estimating residual water volume
from the water level in the cup. Ten cups were randomly selected from the 32 in use.
Starting from an empty state, water was added in 100 mL increments, and the water level
(cm) was measured with a ruler after each addition until the cup was full.
Based on the recorded water-level and volume data, the following regression equation
was developed:
Residual water volume (L) = 0.0287 × (water level in cm)2 + 0.1146 × (water level in cm) (R2 = 0.99).
2.5.3. Flow Rate of Water Cups
The mean flow rates of all 16 cups used by the experimental cows were determined.
The day before the main observation, a preliminary test was conducted to establish the
average flow rate for each of the four time periods.
For each cup, the flow rate was measured three times per period. Specifically, each
cup was filled to capacity, and the paddle was pressed for 10 s; the overflow was collected
in a bucket and weighed to record the dispensed volume (L/10 s). The recorded volumes
were then converted to flow rates in L/s. For each cup, the interval-specific mean flow
rates (L/s) were applied in the water intake calculations.
The flow rates ranged from 0.19 to 0.33 L/s (11.4–19.8 L/min), with all cups meeting the
minimum requirement of 10 L/min for drinking facilities specified by Welfare Quality® [25],
Zappavigna et al. [26], and RSPCA [27], which apply broadly to drinking facilities.
Using the above method, first the residual water level in the cup was measured with a
ruler before drinking behaviour, then the duration of the drinking event was timed when
drinking was observed, and finally the residual water level was measured again after
drinking to calculate the intake for each drinking event.
2.6. Behavioural Observation
Prior to data collection, both observers were trained together at the study farm to ensure consistency in their assessments. Behavioural observations were primarily conducted
by a single trained observer, and a second observer provided supplementary coverage
during short breaks to avoid fatigue. Although formal inter-rater reliability testing was
not conducted, the observers were trained together and periodically cross-checked their
observations to ensure consistency.
Observations were conducted from approximately 1.5 m in front of each stall, allowing
a clear view of the cow’s muzzle and the water cup without disturbing the animals. The
barn was illuminated by natural daylight from side windows, supplemented by ceilingmounted LED lighting to maintain consistent visibility throughout all observation periods.
Behavioural observations were conducted concurrently with water-intake measurements during the same four daily intervals described above (totaling 11 h per day). Each
observation day, one or two adjacent cows sharing the same water cup were observed.
Drinking behaviour was recorded only when the experimenter was not performing milkyield measurements, and was defined as starting when the cow’s muzzle contacted the
water surface and ending when it was lifted away. Water-flow duration (timed with a
stopwatch) and post-drinking water level (measured with a ruler) were recorded for each
drinking event, except when the duration was too brief to confirm drinking. A predefined
ethogram was used to classify non-drinking behaviours during the observation periods.
Feeding was defined as head inside the feed trough while ingesting or manipulating feed.
Rumination was defined as rhythmic chewing of cud and was recorded separately in
standing and lying positions. Resting was defined as inactive behaviour without feeding
or ruminating and was also distinguished between standing and lying postures. Standing
was defined as upright with all four hooves bearing weight, and lying was defined as the
abdomen or thorax in contact with the floor. These behaviours and postures were recorded
by direct visual observation at 5-min intervals using a time-sampling method.
2.7. Milk Yield Measurement
Milk yield was measured on the same days as water intake measurements. At
each morning and evening milking, a milk meter (Milk Meter FV; TRU-TEST, Auckland,
New Zealand) was attached to the milking unit, and the yield at each milking was recorded
to calculate daily milk yield.
2.8. Cleaning of the Water Cups
After completing the measurements on Day 1, the water cups were cleaned. Baking
soda was sprinkled into each cup, and they were scrubbed with a brush [28]. Cleaning
continued until all four contamination scores shown in Table 1 were zero.
2.9. Temperature and Humidity
Ambient temperature and relative humidity inside the barn were measured using
an environmental meter (LM-8010; FUSO Co., Ltd., Tokyo, Japan). Measurements were
recorded at 30-min intervals from the start of behavioural observations until the end of
the study, and the mean of these values was calculated. The temperature–humidity index
(THI) was then calculated as follows:
THI = 0.8 × T + 0.01 × RH × (T −14.3) + 46.3,
where T is ambient temperature (◦C) and RH is relative humidity (%). This formula was
selected because it is widely used in cattle heat-stress research and is suitable for evaluating
thermal conditions in humid barn environments [29].
2.10. Statistical Analysis
Comparisons of water intake, drinking frequency, behaviours, postures, daily milk
yield, and THI before and after cup cleaning were performed using the Wilcoxon signedrank test because the data consisted of paired measurements from the same cows and
did not satisfy the assumptions required for parametric tests. Correlations between THI
and daily water intake, and between THI and water intake per bout, were assessed using
Spearman’s rank correlation coefficient, as these variables showed non-normal distribution
patterns typical of behavioural and intake data. For all analyses, a significance level of
p < 0.05 was adopted.
Twenty-eight cows using 16 cups were investigated; two were excluded because they
exhibited non-consumptive pressing of the drinker without ingesting water [30] or water
lapping [31–34], behaviours that caused excessive overflow from the cups, preventing
accurate measurement. Two additional cows were excluded because drinking frequency
during milk-yield recording exceeded 20% of total drinking frequency. The final analysis
therefore included 24 cows using 15 cups. The mean parity of these cows was 3.5 ± 1.8 (SD),
and the mean days in milk (DIM) was 204.7 ± 69.8 (SD). The characteristics of the cows
and their milk yield during the observation period are summarized in Table 2.
| Cow ID | Parity | DIM (Days) | Milk Yield (kg/day) Mean ± SD |
Minimum | Maximum |
|---|---|---|---|---|---|
| 690 | 7 | 285 | 32.8 ± 0.7 | 32.0 | 33.6 |
| 702 | 6 | 76 | 47.0 ± 2.3 | 44.4 | 50.0 |
| 717 | 7 | 217 | 30.1 ± 1.3 | 28.4 | 31.4 |
| 726 | 6 | 105 | 30.2 ± 1.2 | 28.7 | 31.6 |
| 756 | 6 | 190 | 30.5 ± 2.2 | 27.6 | 32.9 |
| 825 | 5 | 283 | 23.3 ± 0.6 | 22.8 | 24.2 |
| 880 | 4 | 148 | 45.0 ± 0.7 | 44.5 | 46.0 |
| 904 | 4 | 277 | 13.0 ± 0.4 | 12.6 | 13.5 |
| 909 | 4 | 207 | 35.4 ± 1.5 | 34.1 | 37.5 |
| 953 | 4 | 139 | 45.0 ± 1.5 | 43.0 | 46.5 |
| 958 | 3 | 283 | 35.7 ± 0.6 | 34.9 | 36.4 |
| 961 | 3 | 255 | 33.6 ± 0.9 | 32.5 | 34.6 |
| 963 | 3 | 115 | 46.1 ± 1.8 | 43.8 | 48.3 |
| 964 | 3 | 181 | 34.7 ± 0.4 | 34.2 | 35.0 |
| 965 | 3 | 208 | 36.8 ± 0.8 | 35.7 | 37.5 |
| 1006 | 3 | 124 | 29.2 ± 0.2 | 29.0 | 29.4 |
| 1007 | 3 | 176 | 41.0 ± 1.4 | 39.3 | 42.8 |
| 1015 | 2 | 157 | 45.0 ± 0.7 | 44.1 | 45.6 |
| 1016 | 2 | 282 | 29.0 ± 1.3 | 27.5 | 30.6 |
| 1018 | 2 | 290 | 27.0 ± 0.0 | 27.0 | 27.1 |
| 1105 | 2 | 125 | 34.7 ± 0.8 | 33.9 | 35.8 |
| 1122 | 1 | 287 | 24.8 ± 1.0 | 23.5 | 26.0 |
| 1123 | 1 | 285 | 20.5 ± 0.4 | 20.0 | 21.1 |
| 1131 | 1 | 218 | 30.9 ± 0.9 | 29.7 | 31.9 |
3. Results
3.1. Environmental Conditions
In the present study, treatments were conducted on consecutive days under similar
ambient and water temperatures. The mean temperature–humidity index (THI; min–max)
was 56.2 (41.0–68.6) before cleaning and 55.4 (41.4–66.6) after cleaning, with both values
well below 72, a value above which adverse effects of heat stress on high-producing dairy
cows have been reported [35]. No significant difference in mean THI was detected between
the two treatment days (Wilcoxon signed-rank test, p = 0.30).
Spearman’s rank correlation revealed no significant association between mean THI
and total water intake (pre-cleaning: rs = 0.00, p = 0.98; post-cleaning: rs = −0.21, p = 0.30).
Similarly, no significant association was observed between mean THI and water intake per
drinking bout (pre-cleaning: rs = 0.01, p = 0.95; post-cleaning: rs = −0.20, p = 0.32).
3.2. Drinking Behaviour and Water Intake
Table 3 shows changes in drinking behaviour before and after water cup cleaning. The
number of drinking bouts showed no significant difference between treatments. In contrast,
total water intake increased significantly after cleaning (p < 0.05), with cows consuming
approximately 5 L more water per day.
| Item | Pre-Cleaning | Post-Cleaning | p-Value |
|---|---|---|---|
| Number of drinking bouts | 13.0 ± 13.0 | 12.1 ± 13.0 | ns |
| Total water intake (L/day) | 83.1 ± 30.5 | 88.8 ± 30.6 | * |
| Water intake per drinking bout (L) 1 | 10.2 ± 6.2 | 12.4 ± 8.4 | ** |
| Milk yield (kg/day) | 33.5 ± 8.8 | 33.2 ± 8.4 | ns |
1 Calculated as total water intake (L) divided by the number of drinking bouts. 2 Wilcoxon signed-rank test. * p < 0.05; ** p < 0.01; ns, not significant.
Water intake per drinking bout also increased significantly following water cup cleaning (p < 0.01), with cows consuming approximately 2 L more water per bout. Considerable
variation among cows was observed for drinking behaviour and water intake variables, as
reflected by the relatively large standard deviations (Table 3).
3.3. Milk Yield
Daily milk yield did not differ significantly before and after water cup cleaning
(p > 0.05). Mean milk yield remained approximately 33 kg/day under both conditions
(Table 3).
4. Discussion
The present study demonstrated that cleaning water cups increased total water intake
and water intake per drinking bout in lactating cows housed in a tie-stall barn, while the
number of drinking bouts remained unchanged. These findings suggest that water cup
cleaning improved drinking efficiency without altering drinking frequency.
Previous studies comparing environmental conditions have shown that drinking
water intake in dairy cows varies widely depending on temperature and physiological
status. Meyer et al. [36] reported substantial individual variation in daily water intake,
ranging from 14 to 171 kg/day, with higher ambient temperatures and higher milk yield
significantly increasing water intake. Similarly, Krauß et al. [37] observed large differences
in water intake between cows housed in different milking systems. In the present study,
temperature–humidity index values remained within a moderate range on both observation
days, indicating that climatic conditions were relatively stable. Accordingly, the observed
increases in water intake are unlikely to have been driven by environmental variation and
are more plausibly attributed to the direct effects of water cup cleaning.
The increase in water intake following cleaning occurred primarily through an increase in water intake per drinking bout rather than an increase in drinking frequency.
This finding indicates that water cup cleaning improved drinking efficiency by altering
qualitative aspects of drinking behaviour rather than increasing the motivation to drink.
This pattern is consistent with previous studies showing that improved water cleanliness
affects drinking characteristics such as intake per bout, pauses, and exploratory behaviours,
without necessarily increasing drinking frequency [15,16].
The present study extends these findings to a tie-stall barn with individual water cups,
demonstrating that improved water hygiene can enhance drinking efficiency even in the
absence of alternative water sources or social competition for access.
Large individual variation in drinking behaviour was observed in the present study, as
reflected by the wide standard deviations in drinking bout frequency and water intake variables. Such variation may reflect inherent differences among cows in water requirements
and drinking patterns. In group-housed dairy cows, high ambient temperatures have
been shown to increase competition at drinkers, resulting in more frequent displacements
and altered drinking patterns [38]. In such systems, automated longitudinal monitoring
has further demonstrated that social hierarchy influences drinking frequency, timing, and
daily water intake, with subordinate cows modifying drinking behaviour to avoid peak
competition periods [39]. In contrast, cows in the present tie-stall barn did not compete for
access to water cups, suggesting that the observed variability was more likely related to
intrinsic differences in drinking strategy, metabolic demand, and habitual patterns of water
use rather than social factors.
The fouling scores of the water cups ranged from 3 to 5, indicating moderate to high
levels of contamination prior to cleaning. However, the extent to which this variability
influenced the magnitude of the observed effects was not directly assessed in this study and
therefore remains unclear. In general, contamination of drinking facilities may reduce water
palatability and consequently influence intake and drinking behaviour. Thus, differences
in the degree of contamination may lead to variation in the magnitude of changes in water
intake and drinking patterns. Therefore, the magnitude of the effects observed in this study
may have been partly influenced by differences in the pre-cleaning contamination status of
the water cups.
Despite the observed increase in water intake, daily milk yield did not differ before
and after water cup cleaning. This finding should be interpreted in the context of the
already high production level of the cows and the moderate climatic conditions during the
study period. The cows in the present study produced approximately 33 kg of milk per
day on average, which is at the higher end of the range typically reported for commercial
Holstein herds in Japan under thermoneutral conditions. Previous studies have shown
that responses of milk yield to changes in water-related conditions are most pronounced
under conditions of severe water restriction or environmental heat stress, whereas under
non-stressful conditions, short-term or moderate changes in water availability may alter
drinking behaviour without affecting milk yield [3,24,35,40]. Under the conditions of the
present study, therefore, the primary benefits of water cup cleaning are better interpreted
as improvements in drinking efficiency and water hygiene rather than immediate increases
in milk production.
Several limitations of this study should be considered. The experimental design did
not include a negative control (i.e., water cups that were not cleaned) because, after applying
the selection criteria described in the Materials and Methods, the number and configuration
of eligible cows and water cups did not allow the establishment of an independent control
group of sufficient size. Therefore, a within-animal comparison design was adopted
to control for individual variability. Consequently, the observed effects may have been
influenced not only by the cleaning treatment but also by day-to-day variation. Although
the within-animal comparison design reduced individual variability, potential confounding
effects associated with the sequential measurement design cannot be fully excluded.
The study was conducted on a single commercial farm with a limited number of cows,
and only one type of water cup was evaluated, which may limit the generalizability of the
findings. Dry matter intake was not measured, and the experiment was based on single-day
observations, making it difficult to account for temporal variation. Future studies should
include longer observation periods covering multiple days in order to capture temporal
variation and longer-term responses.
Microbiological analyses and comparisons among different cleaning methods were not
performed, as this was beyond the scope of the present study and constrained by practical
limitations in on-farm sampling. In addition, residual odor after cleaning, particularly due
to the use of baking soda, may have influenced drinking behaviour.
The relatively high fouling scores before cleaning (3–5) suggest that the observed
response may represent the upper range of the effect. The experiment was conducted
under relatively stable autumn climatic conditions, allowing the isolation of short-term
effects of water cup cleaning while minimizing confounding influences such as heat stress.
However, drinking behaviour and water intake are influenced by heat stress, and therefore
the responses observed here may differ under summer conditions. Furthermore, fouling
scores were not re-assessed after cleaning due to the short observation period and practical
constraints, which limited the evaluation of re-contamination dynamics.
In addition to enhancing drinking efficiency, regular cleaning of water cups may contribute to improved hygiene and a reduced risk of infection associated with contaminated
drinking surfaces. These practical benefits may be particularly important under warm
conditions, when microbial growth is promoted and adequate water intake becomes critical.
5. Conclusions
In lactating dairy cows housed in tie-stall barns, cleaning the water cups increased
water intake per bout and total intake, improving drinking efficiency without affecting
drinking frequency, behaviour, or milk yield. These effects appear to be directly attributable
to improved water hygiene at the drinking point. From a practical perspective, regular
cleaning of water cups should be incorporated into routine farm management to support
water hygiene and animal welfare. However, further studies are needed to evaluate
the long-term impacts of improved water-cup hygiene on cow health, feed intake, and
productivity under different management and climatic conditions.
Author Contributions: Conceptualization, T.S.; methodology, T.S. and Y.Y.; investigation, N.Y., Y.Y. and
T.S.; data curation, N.Y. and Y.Y.; formal analysis, Y.Y.; visualization, Y.Y. and N.Y.; writing—original draft
preparation, Y.Y.; writing—review and editing, T.S. and Y.Y.; supervision, T.S.; project administration, T.S.
All authors have read and agreed to the published version of the manuscript.
Funding: This research received no external funding.
Institutional Review Board Statement: The study was conducted according to the guidelines of
Obihiro University of Agriculture and Veterinary Medicine and approved by the Ethics Committee of
Obihiro University of Agriculture and Veterinary Medicine (protocol code 19-166 and approval date
4 June 2019).
Informed Consent Statement: Written informed consent was obtained from the owner of the animals
involved in this study.
Data Availability Statement: The data presented in this study are available from the corresponding
author upon reasonable request.
Conflicts of Interest: The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
DIM
Days in Milk
DMI
Dry Matter Intake
MTP
Multiple Trait Prediction
RUP
Rumen-Undegradable Protein
THI
Temperature–Humidity Index
TMR
Total Mixed Ration
References
[1] Togashi, K.; Tanaka, S. The effects of water restriction on physiological responses in fattening beef cattle. Jpn. J. Zootech. Sci. 1979, 50, 320–327.
[2] Ikhatua, U.J.; Ehoche, O.W.; Umoh, J.E. Effects of restricted water on feed intake, nutrient utilization and nitrogen metabolism in Zebu cattle. J. Agric. Sci. 1985, 105, 463–467. [CrossRef]
[3] Little, W.; Collis, K.A.; Gleed, P.T.; Sansom, B.F.; Allen, W.M.; Quick, A.J. Effect of reduced water intake by lactating dairy cows on behaviour, milk yield and blood composition. Vet. Rec. 1980, 106, 547–551. [CrossRef]
[4] Singh, A.K.; Bhakat, C.; Singh, P. A review on water intake in dairy cattle: Associated factors, management practices, and corresponding effects. Trop. Anim. Health Prod. 2022, 54, 154. [CrossRef] [PubMed]
[5] National Academies of Sciences, Engineering, and Medicine (NASEM). Nutrient Requirements of Dairy Cattle; National Academies Press: Washington, DC, USA, 2021. [CrossRef]
[6] Cardot, V.; Le Roux, Y.; Jurjanz, S. Drinking behavior of lactating dairy cows and prediction of their water intake. J. Dairy Sci. 2008, 91, 2257–2264. [CrossRef]
[7] Jensen, M.B.; Vestergaard, M. Invited review: Freedom from thirst—Do dairy cows and calves have sufficient access to drinking water? J. Dairy Sci. 2021, 104, 11368–11385. [CrossRef]
[8] Holter, J.B.; Urban, W.E., Jr. Water partitioning and intake prediction in dry and lactating Holstein cows. J. Dairy Sci. 1992, 75, 1472–1479. [CrossRef] [PubMed]
[9] Moncada Laínez, M.; Hsia, L.C. Effects of season, housing and physiological stage on drinking and other related behavior of dairy cows (Bos taurus). Asian-Australas. J. Anim. Sci. 2004, 17, 1417–1429. [CrossRef]
[10] Lardner, H.A.; Kirychuk, B.D.; Braul, L.; Willms, W.D.; Yarotski, J. The effect of water quality on cattle performance on pasture. Aust. J. Agric. Res. 2005, 56, 97–104. [CrossRef]
[11] LeJeune, J.T.; Besser, T.E.; Merrill, N.L.; Rice, D.H.; Hancock, D.D. Livestock drinking water microbiology and the factors influencing the quality of drinking water offered to cattle. J. Dairy Sci. 2001, 84, 1856–1862. [CrossRef]
[12] Avery, L.M.; Williams, A.P.; Killham, K.; Jones, D.L. Survival of Escherichia coli O157:H7 in waters from lakes, rivers, puddles and animal-drinking troughs. Sci. Total Environ. 2008, 389, 378–385. [CrossRef] [PubMed]
[13] Ministry of Agriculture, Forestry and Fisheries of Japan. Technical Guidelines for Management of Dairy Cattle; Livestock Industry Bureau: Tokyo, Japan, 2023.
[14] Hayer, J.J.; Heinemann, C.; Schulze-Dieckhoff, B.G.; Steinhoff-Wagner, J. A risk-oriented evaluation of biofilm and other influencing factors on biological quality of drinking water for dairy cows. J. Anim. Sci. 2022, 100, skac112. [CrossRef] [PubMed]
[15] Burkhardt, F.K.; Hayer, J.J.; Heinemann, C.; Steinhoff-Wagner, J. Drinking behavior of dairy cows under commercial farm conditions differs depending on water trough design and cleanliness. Appl. Anim. Behav. Sci. 2022, 256, 105752. [CrossRef]
[16] Burkhardt, F.K.; Hayer, J.J.; Heinemann, C.; Steinhoff-Wagner, J. Effect of climatic condition, type of trough and water cleanliness on drinking behavior in dairy cows. Animals 2024, 14, 257. [CrossRef]
[17] Japan Animal Welfare Livestock Association. Animal Welfare Assessment Methods for Dairy Cows. Available online: https:// animalwelfare.jp/ (accessed on 25 August 2025). (In Japanese)
[18] Hagiya, K.; Atagi, Y.; Kawahara, T.; Gotho, Y.; Suzuki, M.; Shirai, T.; Atsumi, T. Comparison of three methods for predicting whole lactation records from test-day records of Holstein cows. Anim. Sci. J. 2004, 75, 345–351. (In Japanese) [CrossRef]
[19] Dado, R.G.; Allen, M.S. Variation in and relationships among feeding, chewing, and drinking variables for lactating dairy cows. J. Dairy Sci. 1994, 77, 132–144. [CrossRef]
[20] Rajala-Schultz, P.J.; Gröhn, Y.T.; McCulloch, C.E.; Guard, C.L. Effects of clinical mastitis on milk yield in dairy cows. J. Dairy Sci. 1999, 82, 1213–1220. [CrossRef] [PubMed]
[21] Souma, K. Water trough/Feed trough. In The System of Production Medicine—Dairy Cow—Part 3; Japan Livestock Industry Association, Ed.; Rural Culture Association: Tokyo, Japan, 2001; pp. 162–169. (In Japanese)
[22] Osborne, V.R.; Hacker, R.R.; McBride, B.W. Effects of heated drinking water on the production responses of lactating Holstein and Jersey cows. Can. J. Anim. Sci. 2002, 82, 267–273. [CrossRef]
[23] Nizzi, E.; Hurtaud, C.; Boudon, A. Interaction between drinker density and cow social dominance affects drinking behavior. JDS Commun. 2024, 5, 400–405. [CrossRef]
[24] Nizzi, E.; Foris, B.; Weary, D.M.; Boudon, A.; von Keyserlingk, M.A.G. Stocking density at feeders and drinkers and temporal feed restriction affects dairy cows’ drinking behavior. JDS Commun. 2025, 6, 104–109. [CrossRef]
[25] Welfare Quality®. Welfare Quality® Assessment Protocol for Cattle; Welfare Quality® Consortium: Lelystad, The Netherlands, 2009.
[26] Zappavigna, P.; Lensink, J.; Flaba, J.; Ventorp, M.; Greaves, R.; Ofner-Schrock, E.; Ryan, T.; Van Gaenegem, L. The Design of Dairy Cow and Replacement Heifer Housing; CIGR Section II Working Group Report; CIGR: Gainesville, FL, USA, 2014.
[27] Royal Society for the Prevention of Cruelty to Animals (RSPCA). RSPCA Welfare Standards for Dairy Cattle. Available online: https://business.rspcaassured.org.uk/membership/rspca-welfare-standards/ (accessed on 25 August 2025).
[28] Nemuro Subprefectural Bureau. Farming Technology Information, 2012. Available online: https://www.nemuro.pref.hokkaido.lg. jp/ss/nkc/gijutsu/jyouhou/222297.html (accessed on 5 May 2026). (In Japanese)
[29] Mader, T.L.; Davis, M.S.; Brown-Brandl, T. Environmental Factors Influencing Heat Stress in Feedlot Cattle. J. Anim. Sci. 2006, 84, 712–719. [CrossRef]
[30] Broom, D.M.; Fraser, A.F. Domestic Animal Behaviour and Welfare; CAB International: Wallingford, UK, 2007.
[31] Albright, J.L.; Arave, C.W. The Behaviour of Cattle; CAB International: Wallingford, UK, 1997.
[32] Roberts, J. Understanding cow behavior. Bov. Pract. 1997, 31, 104–107. [CrossRef]
[33] Mattiello, S.; Arduino, D.; Tosi, M.V.; Carenzi, C. Survey on housing, management and welfare of dairy cattle in tie-stalls in western Italian Alps. Acta Agric. Scand. A Anim. Sci. 2005, 55, 31–39. [CrossRef]
[34] Genther, O.N.; Beede, D.K. Preference and drinking behavior of lactating dairy cows offered water with different concentrations, valences, and sources of iron. J. Dairy Sci. 2013, 96, 1164–1176. [CrossRef]
[35] Armstrong, D.V. Heat stress interaction with shade and cooling. J. Dairy Sci. 1994, 77, 2044–2050. [CrossRef]
[36] Meyer, U.; Everinghoff, M.; Gädeken, D.; Flachowsky, G. Investigations on the water intake of lactating dairy cows. Livest. Prod. Sci. 2004, 90, 117–121. [CrossRef]
[37] Krauß, M.; Drastig, K.; Prochnow, A.; Rose-Meierhöfer, S.; Kraatz, S. Drinking and cleaning water use in a dairy cow barn. Water 2016, 8, 302. [CrossRef]
[38] McDonald, P.V.; von Keyserlingk, M.A.G.; Weary, D.M. Hot weather increases competition between dairy cows at the drinker. J. Dairy Sci. 2020, 103, 3447–3458. [CrossRef]
[39] Foris, B.; Vandresen, B.; Sheng, K.; Krahn, J.; Weary, D.M.; von Keyserlingk, M.A.G. Automated longitudinal measures of drinking behavior provide insights into the social hierarchy in dairy cows. JDS Commun. 2024, 5, 411–415. [CrossRef] [PubMed]
[40] Little, W.; Sansom, B.F.; Manston, R.; Allen, W.M. Effects of restricting the water intake of dairy cows upon their milk yield, body weight and blood composition. Anim. Sci. 1976, 22, 329–339. [CrossRef]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual
author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to
people or property resulting from any ideas, methods, instructions or products referred to in the content.